TransTel Model TD-824-I Digital Telephone System – Programming Forms Manual
Page 65
Form 05-11 - System Parameters Form – Supplemental
G1-a10ao
Form 05-11-T 01 02 03 04 05 06 07 08
Item
Range Of Entries 0 0 0 0 0-3 0-9 0-9 0-8
Default 0 0 0 0 0 0 1 0
05-11-01 – Caller ID Ignore Header Digit:
G1-a10a0
This option is enabled for locations where a non-numeric character precedes the Caller ID
information. The non-mumeric character is not displayed on LCD displays. It is not normally
found in North America.
0=No Entry 1=Header “A” 2=Header “B” 3=Header “C”
4=Header “D” 5=Header “*” 6=Header “#”
05-11-02 - DISA Password:
This parameter when enabled will increase the number of DISA passwords from 1 to 24. At the
default setting of 0 the DISA password will be set in Form 13-02. If the parameter is set to 1, 24
passwords are available and they will be the same as the forced account codes numbers (25-48).
Forced account codes are set in Form 17-(00-48).
0=Disable 1=Enable
05-11-03 – Music On Hold/Ringback on Transfer:
This parameter selects what the incoming caller will hear during Ring Transfer and Hold Recall
conditions. The feature is designed for the U.S. to prevent the caller from hearing recognizing the
TD-824i International Ring Back Tone and mistake it as a disconnect or busy signal and hanging up
even though their call is still in progress.
0 = Ring Back Tone 1 = Music On Hold 2 = Silence
05-11-04. DISA Access Delay NIght Service:
G1-a20m
This parameter sets the time duration that a DISA trunk will ring prior to connection to return dial tone
or VSC message. (Stations can answer during this time.)
0 = Automatic connection, no ring to the stations.
1-8 = Automatic connection after 2-254 seconds ringing as listed below.
Pre: G1-a20m this option controlled the DISA Delayed Answer Timer during both Day Service and
Night Service.
Version G1-a20m and newer: DISA delayed answer timer has day/night mode
The DISA answer delay reference 05-01-04 in day service.
The DISA answer delay reference 05-11-04 in night service.
0=0 second 1=2 seconds 2=4 seconds 3=6 seconds 4=8 seconds
5=15 seconds 6=30 seconds 7=60 seconds 8=120 seconds 9=254 seconds