TransTel Model TD-824-I Digital Telephone System – Programming Forms Manual
Page 131
Form 67 - Hunt Group Pilot Assignment:
67-grp
Group
Num.
Pilot
Number
Hunt
Type
Group
Num.
Pilot
Number
Hunt
Type
01 02
03 04
05 06
07 08
09 10
General:
This program sets Pilot Numbers for Hunting Groups 1 to 10.
Description:
There are 10 Hunt Groups available in the TD-824i. Each Hunt Group is assigned a Pilot Number in this form. The
pilot number can be any valid unused number and will have the same number of digits as the station-numbering
scheme used in the system (2, 3 or 4).
Hunt group pilots can be assigned to be rung from Single Digit DISA.
Once Hunting Ring Type is enabled in Form 67-GP (individual) or 05-06-08 (system wide) ringing this pilot number
will access the stations in the group according to the ringing method selected and the order in which they are
programmed in Mode 68 (Day) and Mode 69 (Night). Each Hunt Group can be from 1 to 5 stations in the TD-824i.
There are 3 types of Ring available, Common Audible, Linear and Circular. These can be controlled on a per hunt
group basis or a system wide basis.
If Common Audible is enabled, then calling the pilot number will ring all available stations programmed on Form 68
(Day Service) or 69 (Night Service).
If Linear Ring is enabled then calling the pilot number will always call the first available station in the order in which
they are programmed in Form 68 or 69.
If Circular Ring is enabled then the stations will be called one after the other for each succeeding call until all have
taken a call and then the Ring will revert to the beginning of the Ring assignment and then repeat the process.
Stations can remove themselves from receiving Hunt calls by using the DND key but this will also prevent them
from receiving direct calls.
It is still possible to call each station in the Hunting group directly by dialing it's own individual station number.
If a station in a Hunt Group has set call forward to a station or another Hunt Group (for instance Voice Mail Group)
then only direct calls to the station will be forwarded. If Hunt calls come to the station and it is call forwarded it will
still ring for the call.
Pilot Number Indicates the Access Code that must be dialed to reach the Hunt Group. It must be a unique
number (it cannot be the same as an extension). It must be within the range of valid numbers for extensions (2 digit
numbering plan 10-69, 3 digit numbering plan 100-699, 4 digit numbering plan 1000-6999).
The hunt type is 0 for common ring,1 for linear and 2 for circular