TransTel Model TD-824-I Digital Telephone System - General Description - Installation - Programming Forms Manual
Page 102 Version 1.3b October 2005
Includes all versions through G1-a20x
Form 39-00 - Sensor Assignment Form – KSU Sensor only:
The SENSOR type may be normally open or normally closed and can be set to be activated in Day
or Night switching or in both. Parameters 39-02 in the TD-824I set each sensor contact to be a
normally open or normally closed type and set whether to work in Day or Night Mode or both
Form 39-Item- 01 02 Name - (Reference Only – Not
programmed in system)
Form 39-
Valid Options for Sensor Item Settings 39-01:
00=Disabled
01=Latch operation (Fire Alarm)
Sensor detects activation, all idle extensions will be rung and all busy extensions will
Hear the alarm tone. The fire alarm will continue for 10 minutes.
Pressing [7][7][7] from the console will stop the fire alarm.
The LCD display will show FIRE ALARM !!!! when the alarm is activated.
02=Non-Latching Operation (Break Alarm)
.The Sensor detects the signal appears, all idle extensions will be rung.
.The Sensor detects the signal disappears, all extensions will stop ringing.
The LCD display will show BREAK ALARM !!!! when the alarm is activated.
03=Door Phone 1 Causes the door open command to activate the relay in the KSU instead of in the
ACP or TD-DPU1 Digital doorphone unit.
Valid Idle Options for Sensor Item Settings 39-02:
0 = Disable Sensor function
1 = Normally Open, Activated for Day Service only.
2 = Normally Closed, Activated for Day Service only.
3 = Normally Open, Activated for Night Service only.
4 = Normally Closed, Activated for Night Service only.
5 = Normally Open, Activated for Day Service and Night Service.
6 = Normally Closed, Activated for Day Service and Night Service
Note: Individual stations can be programmed to not receive the Break Alarm in Mode 45-st-06.
The ring cadence for the fire alarm will be as follows
a B c b A b C b a b
a = 1.25 seconds On b = 0.25 seconds off c = 0.25 seconds on.
If door key has been set in mode 07 and mode 39, the Door key on DSS will get the following indications:
Names or labels may be programmed for each of the system sensors. This name will appear on all LCD displays
whenever the respective alarm is activated. To access the name programming function, press DSS key 3 (CO Line
3) while in Form 39-Sensor.
All stations to be alerted by sensor activation are programmed on Form 17.