Page 12
Rebuilding a Failed Mirror Set
If a SPARE drive was not configured, the steps below will guide you in
rebuilding a failed mirror set.
1. As the BIOS boots press F3 when prompted to enter the RAID
BIOS.
2. Press F1 to dissolve an Array.
3. Press the number of the Mirrored array to be dissolved.
4. Press Y to confirm. Be sure you delete the correct Array.
5. Press ESC to exit the RAID BIOS, then immediately turn off the
computer.
6. Replace the bad drive with a new hard drive of equal or greater
size, then restart the computer.
7. During boot press F3 to enter the RAID BIOS.
8. Press F2 to create an Array.
9. Press F2 to create a Mirrored Array.
10. Answer N for automatic setup.
11. Enter the number of the Source (good) drive.
12. Enter the number of the Destination (new) drive.
13. Answer Y to copy from Source to Destination drive.